Premium IOLs
Newleaf carries a Medical Device Regulation (EU 2017/745) Training Certificate from Allanta Reg.no. DV.O105117
IPCL – the customised REFRACTIVE SOLUTION
The concept of the phakic posterior chamber lens dates back to 1986 when Svyatoslav N. Fyodorov implanted the first phakic IOL in the posterior chamber. In 2007, AddVision introduced the first lens of this principle and has since witnessed and helped shape the development of this concept.
Extensive diopter range +15.0 D to -30.0 D
The IPCL is available in 13 sizes from 11.00mm to 14.00mm
Improved lens design to enhance safety, vault and stability
Simplified loading and insertion of IPCL
Improved service and faster delivery
A completely new treatment option with IPCL Presbyopic to close an important gap in refractive care
Diffractive Hydrophobic binocular PHAse CONtinuity
A technology designed for continuous sharp binocular vision from 40 to 90 cm without compromising distance vision. This Hydrophobic one piece IOL has angulation of 5 degrees and the diopter range is from +10D to +35D with 0.5D increments (Available Cylindrical Powers +0.75D to 3.75D with 0.75 increments) . Provided in a preloaded sub 2 mm incision shooter.
Progressive complementary IOLs with phase continuity
CONTINUOUS FOCUS HYDROPHILLIC
The defocus curve is created with positive spherical aberrations in the centerpart, negative aberrations in the mid-peripheral area and an aberration neutral end-peripheral zone. Because of the absence of “hard” near-far-transitions, loss of light energy and photopic phenomena are brought to a minimum.
Continuous Focus from infinity up to 40cm
Negligible Photopic Phenomena.
Refractive Hydrophilic
Hydrophilic acrilic Bi-aspheric (zero aberration optic) optic, segmented bifocal on the anterior surface. This one piece IOL has zero angulation and the diopter range is from +10D to +36D with 0.5 increments and from +15D to +25D with 0.25 increments. The IOL will be provided with a medicel 1.8 or 2.2 viscoject shooter. Available in:
True Multifocal 3D near addition
EDOF 2D near addition
Toric monofocal
Hydrophobic acrylic aspherical on the anterior, toric on the posterior surface. This one piece IOL has angulation of 5 degrees and the diopter range is from +10D to +35D with 0.5D increments in combination with cylindrical powers from 0.75D to`6D with 0.75 increments. Provided in a preloaded sub 2 mm incision shooter.
Rescue Add-on
Hydrophilic Spherical, True Multifocal or EDOF Correction. For implantation in the sulcus in pseudophakic patients.